Home / Tools / Generation / Solar panel output per square metre

Solar panel output per square metre

Generation per square metre of roof by panel efficiency. Calculations start from checked PVGIS SARAH3 yields for 18 UK towns and cities and apply your roof's orientation and tilt factors.

Your figures and assumptions

Yields checked in PVGIS SARAH3 for 18 UK towns and cities: from 853 kWh/kWp in Glasgow to 1,122 kWh/kWp in Plymouth, at 5 kWp, south-facing, 35 degree tilt.
5 kWp
Your household's use over a year, from your bills or meter.
35 °
0 kWh
Prices and costs (sourced, all editable)
Automatic uses the DESNZ median install cost, MCS-certified installations, April 2025 to March 2026: £1,780 per kW for systems up to 4 kW, £1,697 per kW above 4 kW up to 10 kW, £1,262 per kW above that. It switches band with the system size you set. Installed prices include 0% VAT on installation until 31 March 2027, then 5%.
Type the rate from your own quotes if you prefer it to the DESNZ median.
Starting value: Ofgem price cap, 1 October to 31 December 2026, Direct Debit, GB average, including VAT: 26.32p per kWh. Replace it with the rate on your own bill.
Starting value: Ofgem price cap, same period, 54.83p per day. The standing charge is added to the bill whether or not you have solar: 365 days at 54.83p is £200.13 a year.
This field starts empty on purpose: there is no default SEG rate. SEG rates are set by suppliers, not by the government, and the only floor is above 0p per kWh. Enter the rate on your own supplier's SEG tariff. As a guide to what has been offered, Ofgem's Year 5 annual report put the average offered rate at 10.8p per kWh (April 2024 to March 2025, published December 2025): a dated market statistic, not a rate you will get. Leave the field empty and exports are valued at £0.

Every figure can be changed. For a result fitted to your home, use your own tariff and your own quotes.

Editable estimate, used when a battery is included.
Coverage: 18 UK towns and cities, each with a checked PVGIS yield.
Annual generation: London
5,094 kWh
Live result
Annual generation
5,094 kWh
Generation per kWp
1,019 kWh/kWp
Used in the home
1,783 kWh
Exported
3,311 kWh
SEG rate entered
none
Annual benefit
£469

Monthly generation (kWh)

Strongest month: 616 kWhJanFebMarAprMayJunJulAugSepOctNovDec

Worked example

The same calculation with example values: Plymouth, tilt 30 degrees, other values as in the form.

Annual generation: Plymouth
5,593 kWh
Live result
Annual generation
5,593 kWh
Generation per kWp
1,119 kWh/kWp
Used in the home
1,958 kWh
Exported
3,636 kWh

How the calculation works

Yield scales linearly from your town's checked figure at 5 kWp: double the size gives double the output on the same roof. Orientation and tilt apply the same factors as the main engine, published on the methodology page.

The monthly split uses two checked profiles: the London monthly shares for towns and cities in England and Wales, and the Edinburgh shares for Scotland and Belfast. The shape of the year is the point: summer generates several times the winter level. This modelling choice is stated here and on the methodology page.

Common questions

Why is winter output so low?

Short days and a low sun: in London about 3.6% of annual generation falls in December and about 12.1% in July. That is the normal shape of the solar year in Britain, not a system fault.

What does facing away from south cost?

South-east and south-west lose about 5%, east and west about 20%, and north about 44% against south at the best tilt, on the factors published on the methodology page.

Is the system loss already in the yields?

Yes. The 14% PVGIS system loss is inside the reference figures and is never applied twice.