Home / Tools / System sizing / Ground-mounted solar panels: size and area

Ground-mounted solar panels: size and area

Sizing in power and land area for a ground-mounted array. Calculations start from checked PVGIS SARAH3 yields for 18 UK towns and cities and apply your roof's orientation and tilt factors.

Your figures and assumptions

Yields checked in PVGIS SARAH3 for 18 UK towns and cities: from 853 kWh/kWp in Glasgow to 1,122 kWh/kWp in Plymouth, at 5 kWp, south-facing, 35 degree tilt.
5 kWp
Your household's use over a year, from your bills or meter.
35 °
0 kWh
Prices and costs (sourced, all editable)
Automatic uses the DESNZ median install cost, MCS-certified installations, April 2025 to March 2026: £1,780 per kW for systems up to 4 kW, £1,697 per kW above 4 kW up to 10 kW, £1,262 per kW above that. It switches band with the system size you set. Installed prices include 0% VAT on installation until 31 March 2027, then 5%.
Type the rate from your own quotes if you prefer it to the DESNZ median.
Starting value: Ofgem price cap, 1 October to 31 December 2026, Direct Debit, GB average, including VAT: 26.32p per kWh. Replace it with the rate on your own bill.
Starting value: Ofgem price cap, same period, 54.83p per day. The standing charge is added to the bill whether or not you have solar: 365 days at 54.83p is £200.13 a year.
This field starts empty on purpose: there is no default SEG rate. SEG rates are set by suppliers, not by the government, and the only floor is above 0p per kWh. Enter the rate on your own supplier's SEG tariff. As a guide to what has been offered, Ofgem's Year 5 annual report put the average offered rate at 10.8p per kWh (April 2024 to March 2025, published December 2025): a dated market statistic, not a rate you will get. Leave the field empty and exports are valued at £0.

Every figure can be changed. For a result fitted to your home, use your own tariff and your own quotes.

Editable estimate, used when a battery is included.
Coverage: 18 UK towns and cities, each with a checked PVGIS yield.
Annual generation: London
5,094 kWh
Live result
Annual generation
5,094 kWh
Generation per kWp
1,019 kWh/kWp
Used in the home
1,783 kWh
Exported
3,311 kWh
SEG rate entered
none
Annual benefit
£469

Monthly generation (kWh)

Strongest month: 616 kWhJanFebMarAprMayJunJulAugSepOctNovDec

Worked example

The same calculation with example values: Plymouth, tilt 30 degrees, other values as in the form.

Annual generation: Plymouth
5,593 kWh
Live result
Annual generation
5,593 kWh
Generation per kWp
1,119 kWh/kWp
Used in the home
1,958 kWh
Exported
3,636 kWh

How the calculation works

Sizing divides the energy you want by the specific yield of your town and roof: the kWh per kWp from PVGIS SARAH3 (Plymouth 1,122, London 1,019, Glasgow 853 kWh/kWp, south-facing at the best tilt), corrected by the orientation factor and the tilt curve on the methodology page.

Generating as much over the year as you use is not the same as using it all: generation and demand happen at different hours. The solar panel calculator models that gap with the occupancy profiles.

Common questions

Is the yield the same across the UK?

No. At 5 kWp, south-facing at the best tilt, PVGIS gives 5,610 kWh a year in Plymouth and 4,263 kWh in Glasgow: a 32% gap, which shows up as more or fewer panels for the same target.

Should I oversize my system?

Only if your use will grow, for example with an electric car or a heat pump. Oversizing for export earns little: exports are worth only the SEG rate you enter, far below your unit rate.

Does generating 100% of my annual use mean a zero bill?

No. You still buy at night and in winter, export on summer middays, and you pay the standing charge every day regardless: about £200 a year at the current cap. The annual balance evens out totals, not hours.

Related tools

Solar panel calculator · How many solar panels do I need? · What size solar panel system do I need for my electricity use? · How many solar panels fit on my roof?