Home / Tools / Battery storage / Battery degradation year by year

Battery degradation year by year

Capacity fade year by year and its effect on savings. The battery model shifts part of your generation into the evening, with a 92% round-trip efficiency already counted. Battery payback is judged on the UK model: shifted energy gains the gap between your unit rate and your SEG rate.

Your figures and assumptions

Yields checked in PVGIS SARAH3 for 18 UK towns and cities: from 853 kWh/kWp in Glasgow to 1,122 kWh/kWp in Plymouth, at 5 kWp, south-facing, 35 degree tilt.
5 kWp
Your household's use over a year, from your bills or meter.
35 °
0 kWh
Prices and costs (sourced, all editable)
Automatic uses the DESNZ median install cost, MCS-certified installations, April 2025 to March 2026: £1,780 per kW for systems up to 4 kW, £1,697 per kW above 4 kW up to 10 kW, £1,262 per kW above that. It switches band with the system size you set. Installed prices include 0% VAT on installation until 31 March 2027, then 5%.
Type the rate from your own quotes if you prefer it to the DESNZ median.
Starting value: Ofgem price cap, 1 October to 31 December 2026, Direct Debit, GB average, including VAT: 26.32p per kWh. Replace it with the rate on your own bill.
Starting value: Ofgem price cap, same period, 54.83p per day. The standing charge is added to the bill whether or not you have solar: 365 days at 54.83p is £200.13 a year.
This field starts empty on purpose: there is no default SEG rate. SEG rates are set by suppliers, not by the government, and the only floor is above 0p per kWh. Enter the rate on your own supplier's SEG tariff. As a guide to what has been offered, Ofgem's Year 5 annual report put the average offered rate at 10.8p per kWh (April 2024 to March 2025, published December 2025): a dated market statistic, not a rate you will get. Leave the field empty and exports are valued at £0.

Every figure can be changed. For a result fitted to your home, use your own tariff and your own quotes.

Editable estimate, used when a battery is included.

VAT: installation of the system and battery is 0% VAT until 31 March 2027 (HMRC VAT Notice 708/6).

Coverage: 18 UK towns and cities, each with a checked PVGIS yield.
Self-sufficiency: London
45% of your use
Live result
Annual generation
5,094 kWh
Generation per kWp
1,019 kWh/kWp
Used in the home
1,783 kWh
Exported
3,311 kWh
SEG rate entered
none
Annual benefit
£469

The Smart Export Guarantee: how your exports are valued

Under the Smart Export Guarantee (SEG Order 2019), a licensed supplier pays you for metered electricity exported to the grid. The export contract can be with a different supplier from the one you buy from. To be paid you normally need an MCS certificate (or equivalent) for the installation, a meter that can take half-hourly readings, and an export MPAN. The SEG applies in Great Britain only: Northern Ireland is outside the SEG, and export there is arranged with suppliers outside the scheme.

Self-consumed, valued at your unit rate£469
Exported energy3,311 kWh
SEG rateNot entered
SEG income£0
Total annual benefit so far£469

Enter your SEG tariff in the prices section to value your exports. Until you do, exported energy is counted at £0, because there is no standard rate: SEG rates are set by suppliers, not by the government, and the only floor in the rules is above 0p per kWh.

Ofgem, which administers the scheme, reported in its Year 5 annual report (April 2024 to March 2025, published December 2025) that the average SEG rate offered was 10.8p per kWh. That is a dated market statistic about past offers, not a rate you will get: check the current tariff of the supplier you choose. Sources: Smart Export Guarantee Order 2019; Ofgem SEG guidance and Year 5 annual report. Checked 8 November 2026.

VAT: 0% on installation, ending 31 March 2027

Installing energy-saving materials, including solar panels, in residential accommodation is charged at 0% VAT: in Great Britain since April 2022 and in Northern Ireland since May 2023. Batteries fitted as part of an installation have been covered since February 2024. The relief ends on 31 March 2027; from 1 April 2027 the rate becomes 5%. The Autumn Budget 2026 did not extend it. Materials bought supply-only, without installation, are standard-rated.

Source: HMRC VAT Notice 708/6. Checked 8 November 2026.

Worked example

The same calculation with example values: Plymouth, tilt 30 degrees, other values as in the form.

Self-sufficiency: Plymouth
49% of your use
Live result
Annual generation
5,593 kWh
Generation per kWp
1,119 kWh/kWp
Used in the home
1,958 kWh
Exported
3,636 kWh

How the calculation works

A battery raises self-consumption on a diminishing-returns curve: the first kWh shifts a lot of energy, the last very little. The model uses the same curve as the main engine and a 92% round-trip efficiency.

Battery payback is measured only on the extra benefit against the same system without a battery, on the UK model. On tax: installation of panels and batteries is 0% VAT until 31 March 2027. If the verdict is negative, the page says so: the battery can still be a choice for independence, it is not sold as a saving.

Common questions

What size battery should I choose?

As a planning rule, about 1 kWh per 1,000 kWh of annual use and about 1 kWh per kWp of panels, averaged. Beyond a certain size the gains flatten quickly.

Does a battery pay for itself?

Sometimes, because shifted energy gains the gap between your unit rate and your SEG rate. The page works it out with your figures and says so when the answer is no.

What VAT applies to a battery?

Batteries installed as energy-saving materials have been inside the 0% VAT relief since February 2024, whether or not they are fitted with the panels. The relief ends on 31 March 2027, when the rate becomes 5%.

Related tools

Solar battery storage calculator · What size solar battery do I need for my usage? · What size battery for my solar panels? · Usable vs nominal battery capacity