Home / Tools / Technical / Agri-PV basics: coverage and land share

Agri-PV basics: coverage and land share

Coverage, land share and yield basics for agricultural PV. Every calculation shows the formula it uses and separates your inputs from planning assumptions, which are named as such.

Your figures and assumptions

Yields checked in PVGIS SARAH3 for 18 UK towns and cities: from 853 kWh/kWp in Glasgow to 1,122 kWh/kWp in Plymouth, at 5 kWp, south-facing, 35 degree tilt.
5 kWp
Your household's use over a year, from your bills or meter.
35 °
0 kWh
Prices and costs (sourced, all editable)
Automatic uses the DESNZ median install cost, MCS-certified installations, April 2025 to March 2026: £1,780 per kW for systems up to 4 kW, £1,697 per kW above 4 kW up to 10 kW, £1,262 per kW above that. It switches band with the system size you set. Installed prices include 0% VAT on installation until 31 March 2027, then 5%.
Type the rate from your own quotes if you prefer it to the DESNZ median.
Starting value: Ofgem price cap, 1 October to 31 December 2026, Direct Debit, GB average, including VAT: 26.32p per kWh. Replace it with the rate on your own bill.
Starting value: Ofgem price cap, same period, 54.83p per day. The standing charge is added to the bill whether or not you have solar: 365 days at 54.83p is £200.13 a year.
This field starts empty on purpose: there is no default SEG rate. SEG rates are set by suppliers, not by the government, and the only floor is above 0p per kWh. Enter the rate on your own supplier's SEG tariff. As a guide to what has been offered, Ofgem's Year 5 annual report put the average offered rate at 10.8p per kWh (April 2024 to March 2025, published December 2025): a dated market statistic, not a rate you will get. Leave the field empty and exports are valued at £0.

Every figure can be changed. For a result fitted to your home, use your own tariff and your own quotes.

Editable estimate, used when a battery is included.
Coverage: 18 UK towns and cities, each with a checked PVGIS yield.
Annual generation: London
5,094 kWh
Live result
Annual generation
5,094 kWh
Generation per kWp
1,019 kWh/kWp
Used in the home
1,783 kWh
Exported
3,311 kWh
SEG rate entered
none
Annual benefit
£469

Monthly generation (kWh)

Strongest month: 616 kWhJanFebMarAprMayJunJulAugSepOctNovDec

Worked example

The same calculation with example values: Plymouth, tilt 30 degrees, other values as in the form.

Annual generation: Plymouth
5,593 kWh
Live result
Annual generation
5,593 kWh
Generation per kWp
1,119 kWh/kWp
Used in the home
1,958 kWh
Exported
3,636 kWh

How the calculation works

The technical calculations use the formulas shown on each page and the data you enter. Planning figures such as weights, spacings and area factors are named as editable assumptions, not standards.

For electrical checks the page shows the margin it applies: open-circuit voltage on a frosty morning, for example, is worked out with the stated planning margin, always to be confirmed against the data sheets of the components chosen.

Common questions

Do these calculations replace an installer?

No. They are planning calculations with open formulas and stated assumptions. Final electrical and structural design needs the components' data sheets and a professional check.

Why check string voltage in frost?

Because panel voltage rises as temperature falls: the coldest winter morning decides whether the string stays inside the inverter's limit.

Does higher efficiency mean more energy?

Only per square metre. At the same kWp the yield is the same: efficiency decides how much roof you need.

Related tools

Solar panel efficiency calculator · Solar panel watts per square metre · How much do solar panels weigh on a roof? · Roof pitch converter: degrees and percent