Home / Tools / System Sizing / System Size from Annual Consumption

System Size from Annual Consumption

Type in how much electricity your home uses in a year and get the solar system size, in kWp, that would generate the same amount in your city. Set a coverage target below or above 100 percent if you plan to add a heat pump, a car or a battery later.

Your consumption

From a yearly bill or your meter readings.
100 %
Locked PVGIS anchors: Milan 1,365 kWh/kWp, Madrid 1,610 kWh/kWp, Kassel 1,016 kWh/kWp.
35 deg
Coverage: 31 cities in the 10 covered countries, each with a solar yield checked against PVGIS.
Recommended system size for 4,000 kWh a year in Milan, Italy
2.9 kWp
Live result
Energy to generate
4,000 kWh/yr
Yield per kWp here
1,365 kWh
Panels at 450 W
7
Roof area at 1.9 m2 per panel
13.3 m2
Size for 80 percent cover
2.3 kWp
Size for 120 percent cover
3.5 kWp

Monthly production of this size (kWh)

Peak month: 514 kWhJanFebMarAprMayJunJulAugSepOctNovDec

The size is your target energy divided by the yield of one kWp on this roof: 1,365 kWh per kWp per year in Milan, Italy, from the locked PVGIS anchor with orientation and tilt applied. Generating as much as you use across a year is not the same as using it all yourself, because generation peaks at midday in summer. The Solar System Calculator models that timing.

Worked example

A home in Madrid using 3,500 kWh a year, aiming to cover all of it from a south-facing roof at 30 degrees:

Recommended system size for 3,500 kWh a year in Madrid, Spain
2.2 kWp
Live result
Energy to generate
3,500 kWh/yr
Yield per kWp here
1,610 kWh
Panels at 450 W
5
Roof area at 1.9 m2 per panel
9.5 m2

How this is calculated

Recommended size in kWp equals the energy you want to generate divided by the specific yield of your location and roof. The specific yield comes from the locked PVGIS SARAH3 anchors: 1,365 kWh per kWp in Milan, 1,610 in Madrid and 1,016 in Kassel for a south-facing array at the optimal tilt, scaled by the orientation factor and tilt factor for your roof.

Sizing to exactly 100 percent of today's consumption is a common starting point, not a rule. Households expecting an electric car or a heat pump often size to 120 to 150 percent while roof work is being done anyway, because adding panels later costs more per panel than fitting them in one visit. Households that are out all day sometimes size smaller and rely on export, which the payback tools value separately.

Frequently asked questions

How many kWp do I need for 4,000 kWh a year?

In Milan about 2.9 kWp, in Madrid about 2.5 kWp and in Kassel about 3.9 kWp, on a south-facing roof at a good tilt. The difference is purely the local yield per kWp: sunnier places need fewer panels for the same energy.

Should I size my system bigger than my consumption?

Only if your consumption is likely to grow, for example with an electric car, a heat pump or a home office, or if your roof will be scaffolded anyway. Oversizing for export alone rarely pays, because exported energy earns the feed-in rate, not the retail price.

Does covering 100 percent of consumption mean no more bills?

No. You will still import electricity at night and in winter, and export at midday in summer. Annual matching balances the totals, not the timing. Self-consumption and batteries are what close the timing gap.

What if I only know my monthly bill?

Use the panel count tool instead: it converts a monthly bill and your price per kWh into annual consumption, then into panels and kWp.

Related tools

How Many Solar Panels Do I Need? · System Power from Panel Count · System Size for an Electric Car · Solar System Calculator