Home / Tools / System Sizing / String Sizing Calculator
Panels in a string share one inverter input, so their voltages add up. Enter your panel's data sheet voltages and your inverter's limits to find the safe string length window, including the cold-morning voltage rise that sets the maximum.
Method: cold Voc per panel is the data sheet Voc corrected upward by the temperature coefficient over the drop from 25 degrees C to your lowest design temperature. The maximum string is the inverter voltage limit divided by that cold Voc, rounded down. The minimum uses hot-day Vmp, corrected down at a 60 degree cell temperature, against the MPPT minimum, rounded up. Final designs also check MPPT current and the inverter's strings-per-input limits.
A larger 49.5 V panel on a 1,000 V inverter with a 200 V minimum MPPT voltage, in strings of 16:
Panel voltage is not constant. Open-circuit voltage rises as cells get cold, roughly a quarter of a percent per degree, which is why string design uses the coldest bright morning, not the average day: a string that is legal at noon in April can overvoltage the inverter at dawn in January. The maximum string length comes from dividing the inverter's absolute input limit by that cold, corrected Voc.
The minimum comes from the opposite extreme. Working voltage sags as cells heat up, and a string must still clear the inverter's MPPT minimum on a hot afternoon or it underperforms or drops out. Between the two limits sits the window this tool computes; installers then choose string lengths inside it that also fit the roof layout and the inverter's current limits.
Semiconductor band gaps widen as temperature falls, so each cell produces a slightly higher voltage. The effect is small per degree but a 35 degree drop adds roughly 9 to 10 percent to a string's open-circuit voltage.
With a typical 41.5 V panel and a minus 10 degree design temperature, 22 panels: the cold Voc of about 45.4 V divides into 1,000 V twenty-two times. Higher-voltage panels allow fewer per string.
On cold bright mornings its open-circuit voltage can exceed the inverter's maximum input, which risks permanent damage and voids warranties. It is the one string error that is genuinely dangerous to the equipment.
The inverter's tracker cannot hold it at maximum power on hot days, because the working voltage falls under the MPPT floor. The string produces less, or cuts out in heat, rather than being damaged.