Home / Tools / Balcony and Plug-In Solar / Portable Panel and Camping Calculator
Off-grid arithmetic is unforgiving: what you use each day must be made each day, and December is not July. Size the panel for your daily load in the region you travel, and the battery that carries you through the days the sun does not show.
| Month | Your 200 W panel makes per day | Against your 600 Wh load |
|---|---|---|
| January | 531 Wh | -69 Wh |
| February | 727 Wh | +127 Wh |
| March | 869 Wh | +269 Wh |
| April | 1,038 Wh | +438 Wh |
| May | 1,120 Wh | +520 Wh |
| June | 1,217 Wh | +617 Wh |
| July | 1,236 Wh | +636 Wh |
| August | 1,149 Wh | +549 Wh |
| September | 968 Wh | +368 Wh |
| October | 734 Wh | +134 Wh |
| November | 489 Wh | -111 Wh |
| December | 502 Wh | -98 Wh |
The December panel figure is the one winter travellers must respect: it is three to five times the annual-average requirement. Nobody carries that panel, which is why real winter setups combine a modest panel, a large battery, engine or site power as the backstop, and honest rationing of the load. The table shows your own panel's month-by-month position so the rationing is planned, not discovered.
A hungrier setup, fridge and laptop in a Kassel winter pattern, with three days of buffer:
Panel sizing divides the daily load by the daily yield per watt, from the locked specific yield of the reference city: annually averaged for the headline, and by December's monthly share for the winter figure. Portable panels are assumed to be angled reasonably and moved with the sun when you are there to move them, which real campers do.
Battery sizing is load times autonomy days, divided by the usable depth of discharge: the nameplate Wh of a power station is not the Wh you may spend, and lead-acid's 50 percent limit is why lithium stations of half the weight do the same job.
A compressor fridge at roughly 400 Wh a day, plus lights and phones, lands near 600 Wh: about 140 W of panel on annual average in Madrid conditions, 230 W in Kassel, and far more in December. The month table gives your load's figures.
The same seasonal split as rooftops, sharpened by travel: December days are short, the sun is low and often clouded, and heating loads arrive just as generation collapses. Summer trips are easy by comparison.
Load times the sunless days you want to survive, divided by the usable depth: 600 Wh a day and two days of buffer on lithium means roughly a 1,500 Wh station. Buy for the usable figure, not the headline.
Yes, from the vehicle's 12 V system, and for van travel that alternator charging is often the real workhorse with solar as the top-up. This calculator sizes the solar side only, deliberately.
Off-Grid System Sizing · Balcony Solar Yield Calculator · Backup Power Duration Calculator · Peak Sun Hours Calculator