Solar Panel Weight and Roof Load Calculator

Panels are not heavy per piece, but a full array is a car parked on your roof, permanently. Add up panels, mounting and, on flat roofs, ballast, and see the total weight and the load per square metre to compare with your roof's own figures.

Array and mounting

On the data sheet. Current residential panels run about 20 to 26 kg.
Mounting figures are planning averages per m2 of panel footprint, stated as assumptions you can replace with your installer's own numbers by editing the panel count and weight. Ballast varies widely with wind exposure.
Weights are the planning figures you enter. This page adds them up; it does not rate your roof. Only the building's documents or a structural engineer state what a specific roof may carry.
Total weight of this array on the roof
492 kg
Live result
Load per square metre of footprint
21.6 kg/m2
Panels alone
264 kg
Mounting (and ballast if chosen)
228 kg
Panel footprint
22.8 m2
All-in weight per panel position
41 kg

Spread evenly, a pitched array lands near 20 to 25 kg per m2, which most sound pitched roofs were built to shrug off under snow loads many times that figure. Ballasted flat roofs are the case to check properly: ballast, not panels, is most of the weight, and it concentrates at frame feet rather than spreading evenly. This calculator gives you the totals to take to the conversation; the verdict on your roof belongs to its construction documents or a structural engineer, not to a web page.

Worked example

Sixteen heavier 25 kg panels on a ballasted flat roof frame, the heaviest common arrangement:

Total weight of this array on the roof
1,555 kg
Live result
Load per square metre of footprint
51.2 kg/m2
Panels alone
400 kg
Mounting (and ballast if chosen)
1,155 kg
Panel footprint
30.4 m2

How this is calculated

The arithmetic is a sum: panels at their data sheet weight, plus mounting spread over the panel footprint at the planning rate for the mounting type. Ballasted systems replace fixings with weight, holding the frame down against wind uplift with blocks or trays of ballast, which is why their per-metre figure is three to four times a railed roof's.

Two cautions belong with the totals. Point loads matter as well as averages: a ballast tray presses on a small patch of roof covering. And old roofs deserve their own check, because the question is never what solar weighs in general, but what this roof, at this age, was designed and has aged to carry.

Frequently asked questions

How much does a solar panel weigh?

About 20 to 26 kg for a current residential panel, roughly 11 to 13 kg per m2 of glass. Larger commercial-format panels weigh more per piece but about the same per square metre.

How much weight does a full solar system add to a roof?

A 12 panel pitched array totals around 450 to 550 kg including rails, about 22 kg per m2 of footprint. The same array ballasted on a flat roof can pass 1,100 kg.

Can my roof take the weight of solar panels?

Most pitched roofs in sound condition can, comfortably. The honest check is your roof's design load in its building documents, compared with the load per m2 figure here, and a roofer's or engineer's word for older or altered roofs.

Why does ballast weigh so much?

Nothing screws a ballasted frame down; gravity alone resists the wind trying to lift and slide it. The required ballast rises with building height and wind exposure, which is why flat roof figures vary more than any other in this calculator.