Home / Tools / Country, Subsidy and Paperwork / Netherlands Salderen End Calculator (2027)
This calculator is built for the situation its name describes: an annual net metering arrangement, where exported power cancels imported power across the year, giving way to net billing, where you use what you use and export the rest at a lower rate. Every rate in it is a figure you enter, for both arrangements, so you can model the change on your own contract figures and confirm the current official terms that apply to you.
Every money default is an editable estimate, labelled as such. Replace it with the price on your own bill for a result based on your tariff.
The battery slider in the form affects only the net billing side, which is itself the lesson: under annual netting a battery adds nothing to the credit, because timing does not matter; under net billing it shifts exports into self-use at the price gap. The battery payback tool prices that shift on its own.
The same comparison for a 5 kWp system in Madrid, where a larger share of generation is exported:
Net billing is the standard SunIndex model: self-used energy at your electricity price, exports at the feed-in rate you entered, split by your occupancy profile. Annual net metering is the opposite timing assumption: generation first cancels consumption across the whole year at the full price, and only generation beyond total consumption earns the export rate.
The difference between the two annual savings is the value the netting arrangement itself was adding, priced on your rates. The 10-year figure degrades that difference at 0.5 percent a year like every lifetime figure on this site. Both rates and both models are transparent because the real terms of any change, its timing and its treatment of your contract, are official facts you should confirm from the current source, not figures a calculator should assert.
You stop cancelling summer exports against winter imports at the full price. What you use yourself still saves the full price; what you export earns the export rate instead. On the default figures that change is worth about EUR 355 a year on a 5 kWp Milan system, and the form above prices it on your own rates.
Raise the share you use yourself: shift flexible loads into the sun, size the system closer to your daytime use, and consider a battery only where its own payback works, which the battery tools check honestly. Each kWh moved from export to self-use earns the gap between your two rates.
A system sized near your consumption loses least, because its exported share is small. A system much larger than your usage exports the difference at the low rate, which stretches its payback; the payback calculator shows that trade on your profile.
That is set by the official terms and your contract, and it is exactly the kind of date this page will not assert. Confirm the current position from the official source or your supplier, then use this calculator with your rates to price what the change means for you whenever it applies.
Net Metering vs Net Billing Comparison · Poland Net-Billing Calculator · Self-Consumption Rate Calculator · Battery Payback Calculator